Parking robots, garages and industry selection
Adding parking capacity in existing basements without civil reconstruction
Conventional basement car parks lose floor area to human ergonomics: bays are marked 2.4–2.5 m wide so doors can swing open, and double-deep parking is impossible without attendants. Separating drivers from storage bays with JS-M3000-A parking robots turns the interior into a driverless zone: eliminating door-opening gaps trims 0.4–0.5 m per bay width at ±10 mm repeat accuracy, while deep column grids accommodate tandem two-deep or three-deep bays automatically reshuffled by the dispatch system—adding capacity without structural excavation.
Drivers interact only with an entrance transfer bay. On arrival, the driver parks against a wheel stop, locks the car and confirms on the kiosk outside; vehicle-envelope sensors check length, width and height while presence sensors verify no passengers or pets remain inside before the safety gate closes and JS-M3000-A retrieves the car. On departure, advance mobile booking brings the car back facing outwards ready to drive away.
Aisle widths must never be guessed. While JS-M3000-A spins on the spot empty, loaded turns follow Ackermann geometry without sideways crabbing: straight single-lane travel requires at least 2.6 m clear width (2.2 m extreme limit only under strict car-width caps), and 90° loaded turns into bays must be verified by Jiangsong engineers via CAD swept-path simulation against your actual column grid and up to 3.4 m wheelbase.
Fence off unmanned robot storage zones with interlocked access gates and warning signage so pedestrians cannot wander into active lanes, and verify beam and sprinkler headroom during CAD layout.
Frequently asked questions
Can the Jiangsong parking robot run in outdoor surface lots and light rain?
Yes. Rated IP54, it runs outdoors in light rain and crosses standing water up to 20 mm deep on oil-free surfaces within the 3% loaded slope limit.
What aisle width is needed when retrofitting an existing underground car park?
Straight travel lanes need at least 2.6 m clear width, while 90° loaded entry aisles are determined by CAD swept-path simulation on your column-grid drawing.