Jiangsong Robot
Get a quote

Parking robots, garages and industry selection

Integrating with WMS/MES, VDA5050, automatic doors and goods lifts

Connecting upper software and building hardware turns mobile robots into a continuous automated flow. Jiangsong's JS-SYS-RDS-V2.0 communicates bidirectionally with ERP, MES, WMS or AS/RS WCS platforms over standard HTTP/JSON REST APIs: the upper system posts an order ID, carrier code, source, destination and priority, while the scheduler assigns the optimal vehicle, manages traffic and sends real-time status callbacks (assigned, picked, source cleared, dropped, fault) to update inventory locations.

For plants already operating other robot brands or running a corporate fleet manager, Jiangsong supports VDA5050 in both directions: VDA5050-compliant third-party robots can be onboarded into JS-SYS-RDS-V2.0 for unified junction control, or Jiangsong robots can report upward via VDA5050 into your existing master fleet controller—preventing multi-vendor aisle deadlocks.

Fire-zone automatic doors, cleanroom interlocked air showers and multi-storey goods lifts connect through the Jiangsong JS-ACC-DL100 door-and-lift control box. Installed beside the door controller or lift cabinet, JS-ACC-DL100 communicates with JS-SYS-RDS-V2.0 over LAN/Wi-Fi and exchanges optically isolated dry-contact relays or Modbus signals without altering the lift's certified safety circuit.

Interlock step Cross-floor lift sequence Safety interlock
1. Call & wait Robot waits at landing point; scheduler calls lift into dedicated AGV mode Robot holds outside landing line until level & open
2. Hold door & enter JS-ACC-DL100 holds doors open while robot drives slowly into car centre Landing hall calls inhibited while robot boards
3. Travel to floor Once robot confirms full entry and brakes, doors close and target floor triggers Brakes locked throughout vertical travel
4. Exit & release At target floor, doors hold until robot clears landing, then lift returns to normal Timeout or door-sensor mismatch triggers instant alert

Crucial project rule: goods-lift dry contacts (level, door-open, floor-select, door-hold) must be exposed by your lift manufacturer or licensed maintenance vendor—a process that routinely takes 2–4 weeks to approve—so kick off three-party interface sign-off immediately upon order, and always allow 60–120 seconds per lift ride in fleet cycle-time calculations.

Frequently asked questions

Can we deploy multiple robots with JS-SYS-RDS-V2.0 before implementing a WMS or MES?

Yes. Operators can dispatch robots via JS-ACC-CB100 call buttons, tablets or Jiangsong's built-in location-management module, then connect ERP/WMS over HTTP/JSON later.

Can personnel ride inside the goods lift at the same time as an autonomous robot?

For safety, JS-ACC-DL100 places the lift in exclusive AGV mode from call until the robot clears the destination landing, then immediately releases it back to normal use.

Need the full engineering documents?

Site survey forms, recommended spare parts lists by model and battery transport documents are provided for each project. Tell us the model and the site, and we will send the latest version.

Request documents

SEE ALSO

JS-ACC-DL100 door & lift box →  ·  JSVC500 main controller  ·  Dispatch system & accessories  ·  Request interface assessment