Chargers
JS-CHR-A54025-V Automatic charger
Output 54 V 5–25 A. For 54 V models.
This 3D model is schematic: it is based on the dimensions in the specification table. The real product may differ in shape and detail.
Specifications
- Input voltage range (VAC)
- AC220 V±15%
- Input current (A)
- Minimum 7; typical 8; maximum 9
- AC input frequency (Hz)
- Minimum 45; typical 50/60; maximum 65
- Power factor (PF)
- ≥0.99
- Operating temperature range (℃)
- -20℃~45℃ normal operation; 45℃~65℃ derated output
- Operating humidity range
- 5~95%
Input characteristics
- Rated output voltage (VDC)
- 54
- Output voltage range (VDC)
- Minimum 40; maximum 60
- Output current range (A)
- Minimum 5; maximum 25
- Voltage regulation accuracy (%)
- Minimum -0.5; maximum +0.5
- Current regulation accuracy (%)
- Minimum -1; maximum +1
- Maximum power (kW)
- 1.5
- Overall efficiency (%)
- ≥90
- Charging curve
- Stage one, constant-current charging current: 25 A±0.5 A. Stage two, constant-voltage charging voltage: 54 V±0.1 V.
- Load transient performance
- Dynamic response at 25%-50%-75%-100% output load meets the YDT731 standard; overshoot under 5%, recovery time <200 µs.
Output characteristics
- Communication (with battery BMS)
- Online output (automatic charging): blind charging; offline output (manual charging): blind charging
- Communication protocol (with battery BMS)
- Online output (automatic charging): none; offline output (manual charging): none
- Communication (with back end)
- Online output (automatic charging): WiFi; offline output (manual charging): none
Output modes
- Input overvoltage protection point (VAC)
- Yes; typical 285; recovery 270
- Input undervoltage protection point (VAC)
- Yes; typical 165; recovery 175
- Output overvoltage protection (V)
- Yes; typical 62; note: protection: module locks out; recovery: switch the charger off for 30 s, it recovers after restarting
- Output overcurrent protection (A)
- Yes; typical 27; note: protection: module locks out; recovery: switch the charger off for 30 s, it recovers after restarting
- Short-circuit protection
- Yes; note: protection: module locks out; recovery: switch the charger off for 30 s, it recovers after restarting
- Overtemperature protection (℃)
- Yes; maximum 65; recovery 50; note: -20℃~45℃ normal operation; 45℃~65℃ derated output; protection: module shuts down
- Reverse polarity protection
- Yes; note: protects against reversed battery connection when charging in intelligent mode. Commissioning mode does not protect against reversed battery connection.
- Earth protection
- Yes
- Lightning protection
- Yes
- Power cut-off protection
- Yes; note: AC input switch / emergency stop switch
Protection functions
- 485 interface
- 1 channel on the version with the 7 inch touchscreen
- Display
- 7 inch touchscreen
- Cooling
- Forced air cooling
- Altitude
- ≤2000 m
- Protection rating
- IP20
Other functions
- Wire size L
- 1.5 mm²
- Wire size N
- 1.5 mm²
- Wire size PE
- 1.5 mm²
- Rated current
- 10 A
- Rated voltage
- 220 V
- Input cable length
- 3M
Input connection